163
affect the pump accuracy. This procedure is
necessary only on the initial setting of a flow rate.
27. NOTE: Unit should be calibrated upon first time set
up of the machine, beginning of each spray season,
when changing insecticides, every 25 hours of
operation, and after conducting any major overhaul.
AUTOMATIC ENGINE IDLE-BACK
28. The CLARKE Grizzly Cold Aerosol Fog Generator is
equipped with engine idle-back. This device
reduces the engine speed to idle when not spraying.
When the Spray switch is turned on, the engine
speed increases to produce the pre-set pressure at
the nozzle.
29. NOTE: Allow the engine to warm up before turning
the Spray switch ON. A cold engine may stall when
the Spray switch is turned ON.
SPRAYING
30. To turn spray on:
a. On the Remote Control Station, move the Select
Spray/Flush switch to SPRAY.
b. Move the spray switch to ON position. Note that
the red indicator light will be on when the spray is
turned on and the engine speed will increase.