DOD SR400D Especificações Página 155

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 244
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 154
147
 39. Move the high/low selector switch (near the remote
cable hookup point) to the "HIGH" position.
 40. Disconnect
1
/
4
inch formulation line from the "T" on
the spray boom and place into a "pesticide only"
bucket. Use a suitable collection container for
actual pesticide measurement.
 41. Move the function select switch on the remote
control to the "#2" position.
 42. Place the mode switch on the remote control in the
"SPRAY" position.
 43. Place the output switch on the remote control in
the "ON" position (fluid will begin to flow).
 44. Adjust the flow rate knob on the remote control to
the desired level.
 45. Have the timing person signal the beginning and
the end of the one-minute collection period.
 46. Collect sample and compare actual output with
output indicated by remote control digital readout.
 47. If the sample is not within 20% of the volume given
by the remote control digital readout, then contact
the manufacturer, NDVECC or a NEPMU.
Vista de página 154
1 2 ... 150 151 152 153 154 155 156 157 158 159 160 ... 243 244

Comentários a estes Manuais

Sem comentários